Introduction

Air Quality Monitor

User Manual V1.0

The SAWF-07P is a smart indoor air quality monitor that supports 2.4GHz Wi-Fi connectivity and is equipped with a high-definition LCD screen. It provides real-time monitoring and displays data on PM2.5, PM10, as well as temperature and humidity. By connecting to eWeLink, users can access features such as sound and light alarms, receive air quality improvement suggestions, and view historical records through the app. Additionally, the SAWF-07P is compatible with the Matter protocol, enabling control via mainstream smart home platforms.

PM2.5/PM10 Monitor

Temp & Humidity
Monitor

Matter Compatibility

Sound & Light
Alarm

Air Quality Tips

Historical Data
Download

① Wi-Fi Button

  • Press and hold for 5 seconds: The device enters pairing mode. (Pairing time 180 seconds)

② Settings Button

  • Short-press (“temperature unit” flashes): Enter “Menu Mode”.
    • Short-press the “⇌” button: Cycle through adjustable parameters (the current item being edited will flash).
    • Short-press the “+”/”-” button: Calibrate temperature and humidity values / Switch temperature unit / Switch detection mode (PM2.5/PM10)
  • Long-press for 10s: Clear all locally modified parameters by the user and restore the device to its default state.

③ Buzzer/Indicator Light Switch

  • Short-press: Toggle the buzzer on/off.
  • Long-press for 3s: Toggle the LED indicator light on/off.

⚠️When the buzzer goes off:
○ Short-press once: Temporarily mutes the buzzer for a 30-minute silence period.
○ Short-press twice: Completely turns off the buzzer.

④ Multicolor LED Indicator

  • 🟢Green: Air quality is good
  • 🟡Yellow: Air quality is fair
  • 🔴Red: Air quality is poor

⑤ LCD Display

⑥ Power Input Interface (Type-C)

⑦ Stand

⑧ Buzzer Off Icon

⑨ Buzzer On Icon

⑩ Wi-Fi Normal Icon

  ● Flashes slowly: Device is in pairing mode

  ●  Keeps on: Pairing successful

⑪ Wi-Fi Error Icon

⑫ Monitored Value Display

⑬ Concentration Unit

⑭ Current Humidity

⑮ Current Temperature

Specification

Model

SAWF-07P


MCU

ESP32-D0WDR2-V3


Input

5V 1A


Interface type

Type-C


Wireless connection

Wi-Fi IEEE 802.11 b/g/n 2.4GHz


Net weight

127.6g


Color

White


Product dimension

70x103X26mm


Casing materials

PC+ABS


Applicable place

Indoor


Working temperature

-10℃-50℃


Temperature error range

±0.5 ℃; ±1℉


Working humidity

5-95%RH, non-condensing


Humidity error range

±3%


Certification

CE/FCC/RoHS


FCC ID

2APN5-SAWF08P

Matter Ecosystem User Guide

1. Add Device

Open a Matter-compatible App to scan the Matter QR code on the Quick Guide or the device itself to add the device.

Add to Apple

via Matter

Add to Google

via Matter

Add to Alexa

via Matter

Add to SmartThings

via Matter

Add a Device
① Download the eWeLink App

Please download the “eWeLink” App from Google Play Store or Apple App Store.

② Scan QR Code to Add Device

Enter “Scan QR code”

Scan the QR code of the device

Select “Add Device”

Power on the device.
(Do not hold the Wi-Fi button while powering on the device. If this causes a malfunction, restart the device to recover.)

Long press the button for 5 seconds

Check that the “Wi-Fi icon” flashes “two short and one long”.

Search for the device and start connecting

Select the “Wi-Fi” network and enter the password

Device “Added completely”

Installation

This device supports opening the back stand and placing it on a desktop for use.

*Note:

  1. Please ensure that the intake and exhaust ports are not blocked or covered to maintain accurate readings.
  1. Do not place the device in a highly polluted environment for an extended period to avoid damaging the sensor.
Menu Mode Operation Guide

The menu mode allows for manual calibration of temperature/humidity, switching temperature unit (℃/℉), and toggling PM2.5/PM10 detection to improve accuracy.

1. Enter “Menu Mode”

Short-press the “Settings Button”. When the “temperature unit” on the screen starts flashing, it indicates that the device has entered “Menu Mode”.

2. Adjusting Local Display Data

  • Parameter Switching:

Short-press the “⇌” button to cycle through the following adjustable parameters in sequence (the currently edited item will flash): Temperature Unit (°C/°F), Humidity Value, Detection Mode (PM2.5/PM10), Temperature Value.

  • Parameter Adjustment:

Short press the “+” or “-” button to:

    • Calibrate temperature and humidity.
    • Switch the temperature unit (℃/℉).
    • Change the detection mode (PM2.5/PM10).

3. Saving Local Modifications

After cycling through all editable items, continue to short-press the “⇌” button to save all modifications and exit “Menu Mode”.

4. Restoring Original Settings

Long-press the “Settings Button” for 10 seconds to clear all locally modified parameters (including temperature value, humidity value, temperature unit, buzzer status, and indicator light status) that were edited in the “Menu Mode”, automatically restoring the device to its factory default state.

PM2.5/PM10 Concentration Threshold Definition

Good

0~ 35ug/m3

🟢Green LED Indicator

Fair

36 ~ 53ug/m3

🟡Yellow LED Indicator

Poor

>54 ug/m3

🔴Red LED Indicator

Default Comfort Level

Dry

Humidity≤40%RH

Damp

Humidity≥60%RH

Cold

Temperature≤19℃/66.2℉

Hot

Temperature≥27℃/80.6℉

Factory Reset

● After deleting the device in the eWeLink app.
● A device that has been successfully networked in eWeLink can be successfully networked again using a different eWeLink account.
● A device that has been successfully networked in Matter can be successfully re-networked via Matter Bluetooth.