Introduction

Smart Touch Wall Switch

User Manual

The TX Gen2 Smart Wall Touch Switch provides 1-3 channel (1C/2C/3C) control options with a 120-type panel design, supporting neutral-required supply modes. By connecting to Wi-Fi, you can remotely control, set timers, and create automation scenes through the eWeLink app. It is also compatible with the Matter ecosystem, seamlessly integrating with major smart home platforms like Apple Home, Google Home, and Amazon Alexa, enabling cross-brand smart interactions.

Remote Control

Smart Scene

Night Switch Locator

Voice Control

Detach Relay Mode

Share Control

Smart Schedule

Group Control

① Button
● Single press: Turn on/off the smart device
● Press and hold for 5 seconds: Device enters the pairing mode. (Pairing time 10 minutes)

② LED indicator (Blue)
eWeLink Ecosystem:
● Keeps on: Online.
● Slow flash once: Offline.
● Flashes two short and one long: Device is in pairing mode.
● Flashes twice: LAN.

Matter Ecosystem:
● Keeps on: Online.
● Slow flash once: Offline.
● Flashes two short and one long: Device is in pairing mode.

Platform Certification
Specification
Product name

TX Gen2

Product series

TX Series

Product type

Smart Touch Wall Switch

Model

Model T6-1C-120M, T6-2C-120M, T6-3C-120M

MCU

BK7238

Rating

1C: 100-240V~ 50/60Hz 10A Max Resistive load μ

2C: 100-240V~ 50/60Hz 10A/gang, Total 16A Max Resistive load μ

3C: 100-240V~ 50/60Hz 10A/gang, Total 16A Max Resistive load μ

LED load

1C: 150W@100V, 300W@240V

2C: 150W@100V/gang, 300W@240V/gang, Total 300W@100V, 600W@240V

3C: 150W@100V/gang, 300W@240V/gang, Total 450W@100V, 900W@240V

Wireless connectivity

Wi-Fi: IEEE 802.11b/g/n 2.4GHz

Net Weight

1C: 133.3g, 2C: 140.7g, 3C: 149.5g

Dimension

120x74x37.7mm

Color

White

Casing Material

PC+Glass

Diameter of wiring(recommend)

16AWG to 11AWG SOL/STR copper conductor only

Applicable Place

Indoor

Working Temperature

-10°C~40°C

Working Humidity

5%~95% RH, non-condensing

FCC ID

2APN5-T63C120M

Certification

CE/FCC/RoHS

Installation
1. Power off
WARNING
Please install and maintain the device by a professional electrician. To avoid electric shock hazards, do not operate any connection or contact the terminal connector while the device is powered on!
2. Remove the protective cover
3. Panel Removal
4. Wiring instruction

To ensure the safety of your electrical installation, it’s essential either a Miniature Circuit Breaker (MCB) or a Residual Current operated Cicuit-breaker with Integral Overcurrent protection(RCBO) with an electrical rating of 10A, 16A has been installed before the T6-1C-120M(10A), T6-2C-120M(16A), T6-3C-120M(16A).

Make sure all wires are connected correctly.

Instructions for wiring symbols
Terminals
N Neutral Line
L Live Line
L out1 Live Output Terminal__1(100-240V~)
L out2 Live Output Terminal__2(100-240V~)
L out3 Live Output Terminal__3(100-240V~)
After completing the wiring, reinstall the protective cover in the original direction of removal.
5. Installation
Power on

After powering on, the device will enter “pairing mode” during the first use. The LED indicator changes in a cycle of two short and one long flash and release.

*The device will exit the Pairing Mode if not paired within 10mins. If you want to enter this mode, please long-press the button for about 5s until the LED indicator changes in a cycle of two short and one long flash and release.
Matter Ecosystem User Guide

Open a Matter-compatible App to scan the Matter QR code on the Quick Guide or the device itself to add the device.

Add to Apple via Matter

Add to Alexa via Matte

Add to Google via Mattee

Add to SmartThings via Matter

Add a Device
Download the eWeLink App

Please download the “eWeLink” App from Google Play Store or Apple App Store.

Scan QR Code to Add the Device
Enter “Scan”

Scan the QR code on the quick guide or the device

Select “Add Device”

Long press the button for 5 seconds

Check Wi-Fi LED indicator flashing status
(Two short and one long)

Search for the device and start connecting

Select the “Wi-Fi” network and enter the password

Device “Added completely”