Introduction
SONOFF Zigbee Smart Water Valve
User Manual
https://sonoff.tech/en-us/blogs/news/adapter-selection-guide
Remove the old thermostatic faucet and check if a valve adapter is needed, then scan the QR code or enter the URL to select the valve adapter.
With SONOFF Thermostatic Radiator Valve, you can control and reach the temperature you want more accurately. It allows remote control and timing. The window opening detection function helps you save energy and avoid additional energy waste. The matching adapters can be installed on almost any valve.
Remote Control
Smart Timing
Precise Temperature Control
Historical Data Record
Child Safety Lock
Open Window Detection
① Middle button
- When the screen displays “OF”, press and hold for 3 seconds: the device enters pairing mode (pairing lasts for 3 minutes).
- Press and hold for 3 seconds: Child Lock ON/OFF (activate or deactivate the child lock).
② Rotary knob
③ Auto
④ Heating
⑤ Target temperature
⑥ Internet connection
- Flash: Device is in pairing mode
⑦ Low battery
⑧ Configuration key (under the dismountable shell)
- Press & hold for 3 seconds: switches the screen display orientation by 180°.
⑨ Heating valve interface
⑩ Battery case latch
Screen display and introduction
|
Screen display |
Introduction |
![]() |
Window opening detection function The device will automatically identify whether the window is opened after you enter the app interface to enable the window opening detection function. When cold air is detected and the temperature drops more than 1.5 °C within 4.5 minutes, the window opening function will be enabled. Alongside the enabling of the function, the screen displays ” Note: After the window opening function is enabled, the following operations will disable the window opening function: 1. Temperature setting operation on App or device. 2. Temperature rises by more than 1.5℃ within 4.5 minutes. 3. No operation on App or device within 30 minutes.
|
![]() |
Anti-calcification function The temperature control valve will perform a routine calcium removal operation at 12:00 am every Monday to prevent calcification of the valve. During the operation, the screen will display “
|
![]() |
Child lock function Press “Middle button” for 3 seconds, then the screen will display ”
|
![]() |
When heating is not needed in winter, turn knob counterclockwise ( Note: After the antifreeze function is enabled when the room temperature is below 5 °C, the function will be enabled to prevent the radiator from being damaged by freezing. The function will be disabled when the room temperature exceeds 7 °C.
|
![]() |
Low battery Battery needs to be replaced with a new one within 1 week. |
Specification
Product name
Model
TRVZB
MCU
EFR32MG22C224F512GN32
Rating
4.5V ⎓ (3×1.5V AA Batteries)
Battery model
1.5V LR6 Alkaline AA Battery
Zigbee
IEEE 802.15.4
Threaded connection
M30x1.5mm
Temperature setting range
4℃-35℃
Net weight
157g
Working temperature
-10℃~50℃
Working humidity
5~95% RH non-condensing
Color
White
Casing material
PC
Product dimension
Disconnection means
Type 1.B
Pollution degree
2
Rated impulse voltage
500V
Certification
CE/RoHS
Installation
Preparing Before Scanning the QR Code
1.Scanning the QR Code
Press the battery compartment latch while taking out the shell
Open the eWeLink App and scan the QR code on the device
2.Power on the device
Load the batteries
After powering on, the screen displays “
” and flashes
3.Device installation
When “
” stops flashing, install the device to the valve interface.
If the screen displays ”
” or ”
“, press the middle button and “
” will display again.
4.Device debugging
Short press the middle button, and ”
” will flash (Figure ①). Wait for about 5 seconds, and the device will display the initialization interface (Figure ②), which means that debugging is completed.
Add a Device
Download the eWeLink App & Add SONOFF Zigbee gateway
Please download the “eWeLink” App from Google Play Store or Apple App Store.
Matched Gateways
Recommended SONOFF gateway models: ZBBridge-P, ZBBridge-U, NSPanel Pro, iHost
Other compatible SONOFF gateway models: ZBDongle-P, ZBDongle-E, Dongle-M, Dongle-PMG24, Dongle-LMG21
Add the device to Zigbee Gateway
In manual mode, turn the knob counterclockwise. When the screen displays “
“
Press and hold the middle button for 3 seconds
Check the Network Indicator
Status (Flashing)
Select “Add Device”
Select Zigbee gateway
Wait until the addition is done
Temperature control mode
The device supports Auto mode and Manual mode. Shortly press “Middle button” to switch between the two modes.
Auto mode:
When “
” is displayed on screen, it means the auto mode is on
Manual mode:
When “
” disappears on screen, it means the manual mode is on
Screen display rotation
Press the battery compartment latch while taking out the shell
Press“Configuration key” for 3 seconds to change the screen display direction
Error codes, problems and solutions
| Error codes | Problems | Solutions |
| Abnormal temperature sensor |
Contact aftersales staff |
|
| Slow valve operation |
Check installation status and heating valve |
|
| Excessively wide adjustment range |
Check whether temperature controller is fastened |
|
| Excessively small adjustment range |
Check heating valve |
|
| Battery runs out |
Replace battery |
|
| No valve detected |
Check whether valve is installed |
Factory reset
Press “Middle button” for a longer time and at the same time put batteries in, then the screen displays“
”and blinks for 3 seconds. After that, the device is reset to factory settings and is automatically restarted.
All previous settings will be removed after the device is reset to factory settings.